Australia & New Zealand
You are on the right site. Send your RFQ to [email protected] or use the form above. Carlton, VIC team responds during AEST/AEDT office hours.
Send Your RFQ · Carlton-coordinated response
ToneCooling Australia receives RFQs by email at [email protected] or by phone at +61 420 936 669 (mobile, AEST/AEDT office hours). A complete RFQ — TDP map, target ΔP and flow rate, qualification scope, lead time — is reviewed by an engineer, with technical review by the Huizhou design and engineering team, and answered by email with next steps. Includes a thermal sensitivity table, process recommendation (TLP / vacuum braze / FSW / CAB), and draft quote in AUD.
Complete this form and the Carlton VIC customer engineering support team will acknowledge receipt promptly and provide a Carlton-coordinated engineering response promptly during AEST/AEDT office hours.
ToneCooling operates three customer-facing sites by region. Routing your enquiry to the correct entity speeds up engineering response and keeps commercial terms in the correct currency and contract framework.
You are on the right site. Send your RFQ to [email protected] or use the form above. Carlton, VIC team responds during AEST/AEDT office hours.
U.S.-based engineering and procurement teams should engage ToneCooling Texas LLC at tonecoolingtexas.com for U.S. entity contracting and CT-aligned office hours.
Global engineering programmes — Europe, Middle East, Asia, Africa, Latin America — engage the parent group directly at tonecooling.com.
The more complete your RFQ, the faster the engineering response cycle. Below is the field-priority list.
| Field | Why it matters | Required? |
|---|---|---|
| Application (AI server / BESS / power electronics / custom) | Routes RFQ to the correct Huizhou engineering team and reference product family | Required |
| TDP map (W per die or W per cell) | Sets thermal envelope for CFD modelling | Required |
| Target ΔP and flow rate | Sets hydraulic envelope for channel topology | Required |
| Coolant chemistry | Sets thermophysical properties for CFD | Recommended |
| Inlet temperature window (ASHRAE W32 / W40) | Sets boundary condition for AU climate envelope | Recommended |
| CDU model / BMS pump curve | Aligns cold plate ΔP with system pump curve | Recommended |
| Lead-time requirement | Helps the engineering team plan the response track | Recommended |
| Qualification scope (PPAP / AS/NZS / etc.) | Drives validation documentation tier | Recommended |
Three options: (1) complete the RFQ form on this page; (2) email [email protected] with your TDP map, target ΔP and flow rate, qualification scope, and lead-time requirement; (3) call +61 420 936 669 (mobile, AEST/AEDT office hours). Carlton VIC acknowledges receipt and provides a Carlton-coordinated engineering response promptly during AEST/AEDT office hours, with technical review by Huizhou.
Application area, TDP map, target ΔP & flow rate, coolant chemistry, inlet temperature window, CDU/BMS pump curve, lead-time requirement, qualification scope. View the table above or the RFQ input checklist.
prompt acknowledgement; Carlton-coordinated engineering response with technical review by Huizhou; within standard turnaround NDA; promptly DFM session; agreed at quotation.
Carlton VIC customer engineering support office: Suite 69, 139 Cardigan Street, Carlton VIC 3053. Cold plate design + engineering + manufacturing at our own IATF 16949-aligned manufacturing facility in Huizhou, Guangdong, China.
Commercial terms — currency, payment schedule, and incoterms — are agreed by separate written commercial agreement during the quotation process, in line with B2B engineering supply industry practice. All quotes are issued in AUD with line pricing typically GST-exclusive (10 % GST at invoice).