Pre-sales engineering support
RFQ intake, requirements clarification, TDP map review, manifold sketch review, qualification scope review. First-line technical contact for AU buyers.
About ToneCooling Australia Pty Ltd
ToneCooling Australia Pty Ltd (ABN 96 653 174 040) is the Australian customer engineering support and supply entity within the ToneCooling group. Based in Carlton, Victoria, the AU subsidiary serves Australian and Oceania markets with customer engineering support, project coordination, AS/NZS compliance documentation, and pre-sales engineering consultation. Cold plate design, engineering, and manufacturing — including channel-topology design, CFD simulation, process engineering (TLP diffusion bonding, vacuum brazing, friction stir welding, controlled atmosphere brazing), DFM iteration, and quality validation — are performed at our own IATF 16949-aligned manufacturing facility in Huizhou, Guangdong, China, operating under ISO 9001:2015 with an IATF 16949-aligned quality system and documented lot traceability.
Request a Quote View Core IP
Section 1 of 6
ToneCooling Australia operates as the AU customer engineering support and supply entity for the parent ToneCooling group. The Carlton VIC team's scope:
The Carlton team does not perform core product engineering — channel-topology design, CFD simulation, process engineering, DFM iteration, manufacturing, and quality validation are all performed at our Huizhou manufacturing facility per IATF 16949-aligned quality system controls.
| Registered name | ToneCooling Australia Pty Ltd |
| ABN | 96 653 174 040 |
| ACN | 653 174 040 |
| Founding year (AU) | 2022 |
| Registered office | Suite 69, 139 Cardigan Street, Carlton VIC 3053, Australia |
| Phone | +61 420 936 669 |
| [email protected] | |
| GST | Registered (10% applied at invoice) |
| Modern Slavery Act | voluntary supply-chain transparency applied |
Section 2 of 6
RFQ intake, requirements clarification, TDP map review, manifold sketch review, qualification scope review. First-line technical contact for AU buyers.
Time-zone-aligned communication between AU customer and the Huizhou design and engineering team. NDA execution, DFM session scheduling, milestone tracking.
Documentation pack handoff to the licensed AU electrical installer's compliance review (AS/NZS 5139 / 4777 / 60068 / 60529 / 9227).
AUD quoting, GST handling, ChAFTA Certificate of Origin coordination, AU customs documentation, payment terms management.
AU customs clearance support, in-AU after-sales technical support, replacement / RMA coordination, lot-traceability follow-through.
Australian and New Zealand customer support; Pacific Islands reach via AU-based logistics.
Section 3 of 6
Engineering aligned to the Open Compute Project DC-MHS specification for AI server programmes (e.g. NVIDIA GB200 NVL72); thermal envelope per ASHRAE TC 9.9; AS/NZS scope mapped to Standards Australia.
Section 4 of 6
The ToneCooling group is established to engineer precision thermal management hardware for the emerging power electronics and energy storage sectors.
First-generation vacuum brazing line operational; cold plate manufacturing scales to industrial volume.
Dedicated thermal management R&D programme commissioned — peer-reviewed publications and patent filings begin.
Proprietary Transient Liquid Phase diffusion bonding process protected under invention patents; production line transitions from vacuum brazing to TLP for premium copper cold plates.
Engineering R&D pipeline broadened to cover AI server, BESS, power electronics, and industrial cold plate applications.
Australian subsidiary registered (ABN 96 653 174 040) in Carlton, Victoria, to serve Australian and Oceania customer engineering support.
Primary manufacturing facility expanded to support AI server platform demand and BESS programme growth.
Cumulative production volume crosses 1,000,000+ cold plates annually; lot-traceable QMS continues to scale.
Major Huizhou facility upgrade in 2026 — primary manufacturing footprint expanded to 30,000 m² to support next-generation AI server platforms (GB200 / GB300) and Australian grid-scale BESS programme growth. Australian site launched at tonecooling.com.au to serve AU customer engineering support and supply with locally-published technical reference content.
The ToneCooling group operates an in-house engineering R&D programme covering thermal management physics, CFD methodology, materials joining, and process engineering. Output: continuously expanding patent portfolio, peer-reviewed engineering publications, and an integrated design and engineering team supporting the IATF 16949-aligned manufacturing facility in Huizhou.
The ToneCooling group operates three customer-facing websites, each with a distinct regional and engineering role:
Global engineering and product authority site. Cold plate, vapor chamber, AIO, manifold, and thermal management product depth for global OEM and engineering teams.
ToneCooling Texas LLC — U.S. company entity for North American customer trust, U.S. market RFQ coordination, and local engineering support continuity for U.S.-based OEMs.
ToneCooling Australia Pty Ltd — Australian customer engineering support and supply entity for AS/NZS-aligned cold plate programmes. Carlton, Victoria team.
Each site has a distinct regional and content role — the three sites support each other but are not duplicates. Australian customers should engage tonecooling.com.au; U.S. customers should engage tonecoolingtexas.com; global engineering programmes engage the parent site directly.
Section 5 of 6
Proprietary Transient Liquid Phase diffusion bonding for copper cold plates that see heavy thermal cycling. Eliminates brittle braze-filler interlayer.
Mature vacuum brazing line for legacy hyperscaler-grade GPU / CPU cold plates and aluminium product families.
Robotic FSW lines for aluminium plate joining — heavy-EV battery cold plates, marine electrification thermal hardware.
BESS cold plate joining — TC-1P104S and aluminium battery thermal hardware. Same family as Tier-1 automotive battery cold plates.
High-precision steel-to-aluminium frame attachment with minimal heat-affected zone. PFAS-free steel substrate compatible.
ANSYS Fluent / Star-CCM+ CFD; ultrasonic C-scan 100% production inspection; helium leak ≤ 1×10⁻⁹ mbar·L/s; CMM dimensional verification.
Section 6 of 6
In line with B2B engineering supply industry practice, customer programme references and awards are disclosed under mutual NDA on a case-by-case basis. Reach out via the contact page to begin the qualification conversation.
Frequently Asked
ToneCooling Australia Pty Ltd (ABN 96 653 174 040) is the Australian customer engineering support and supply entity within the ToneCooling group. Based in Carlton, Victoria; serves AU and Oceania markets with customer engineering support, project coordination, AS/NZS compliance documentation, and pre-sales engineering consultation.
Customer engineering support, project coordination, AS/NZS compliance documentation handoff, AUD commercial coordination, AU customs handling, and after-sales support. Carlton does NOT perform core product engineering — design, CFD, process engineering, manufacturing, and validation are all at our Huizhou manufacturing facility.
At our own IATF 16949-aligned manufacturing facility in Huizhou, Guangdong, China — channel-topology design, CFD simulation, process engineering (TLP, vacuum brazing, FSW, CAB), DFM iteration, manufacturing, and quality validation. ISO 9001:2015 + IATF 16949-aligned quality systems with lot-traceable QMS.
The ToneCooling group has been engineering thermal management since 2004. 30,000 m² primary manufacturing facility in Huizhou (expanded 2026), 1,000,000+ cold plates annually, 200+ staff (40 % technical), patented manufacturing IP portfolio. In-house engineering R&D programme covering thermal management physics, CFD methodology, materials joining, and process engineering.
Proprietary TLP (Transient Liquid Phase) diffusion bonding; vacuum brazing; friction stir welding (FSW); controlled atmosphere brazing (CAB); laser welding. Materials: copper C1100/C1020, aluminium AL3003MOD/AL4045/6061/6063, SPCC steel.
Customer recognition awards, programme references, and testimonials are coordinated under mutual NDA on a case-by-case basis — standard B2B engineering supply practice. Available to qualified buyers after NDA execution.
Continue Exploring
5 solution areas — AI server, data centre, BESS, power electronics, industrial cold plates.
View hub → HUB4 product families — GPU, CPU, BESS (TC-1P104S), and custom OEM cold plate manufacturing.
View hub → HUB4 engineering pillars — TLP diffusion bonding, DFM, validation, AS/NZS compliance support.
View hub → CONTACTAn engineer reviews every RFQ and replies by email with next steps. [email protected] · +61 420 936 669.
Send RFQ →Send your design brief; the Carlton customer engineering support team will coordinate the engagement with the Huizhou design and engineering team and reply by email with next steps.
Contact ToneCooling Australia