CPU Cold Plate · Phase 1 Primary Product

Server CPU Cold Plate Kits for Australian Buyers

Cold plate kits for two server CPU families: AMD EPYC SP5 (LGA6096 socket — supporting Genoa, Bergamo, Genoa-X, Turin generations, 400 W per socket reference) and Intel Birch Stream (Granite Rapids, Sierra Forest, 350–500 W reference). Both options available in vacuum-brazed copper (hyperscaler grade, helium-leak certified) or skive-and-bond (cost-sensitive volume) configurations. Channel topology and fin pitch tune to your CDU's pressure-drop budget. Cold plates designed, engineered & manufactured at our own IATF 16949-aligned manufacturing facility in Huizhou; AS/NZS support from Carlton VIC.

2CPU platforms (SP5 / Birch Stream)
350–500 Wper-socket TDP envelope
15–25 kPatypical ΔP at 5–8 L/min
4–6 weekstypical prototype lead time
Request a Quote
ToneCooling AMD EPYC SP5 LGA6096 cold plate vacuum-brazed copper construction
Process & standards glossary (AU engineering reader): TLP = Transient Liquid Phase diffusion bonding · FSW = Friction Stir Welding · CAB = Controlled Atmosphere Brazing · PPAP = Production Part Approval Process · ISO 9001:2015 (quality management) · AS/NZS 60068-2-14 ≡ IEC 60068-2-14:2009 (thermal cycling endurance) · IEC 62619:2017 (industrial battery safety) · AS/NZS 5139:2019 (BESS installation) · AS/NZS 4777.2:2020 (grid-connected inverter).
Page reviewed by ToneCooling Australia Customer Engineering Support Team · Carlton, VIC · Last reviewed: 28 April 2026 · About the team →

Server CPU cold plate specifications

Verified design-rated specifications for ToneCooling direct-to-chip CPU cold plates. Values are validated at the stated working point; final values are confirmed per drawing, TDP, flow rate and pressure-drop limit.

AMD EPYC SP5 CPU cold plate

Heat dissipation (design-rated)550 W × 2 (dual socket)
Cold plate materialCopper C1100
Joining processConfirmed at quotation (DFM review)
Working point42 °C, 1 L/min, 25% EGW
Flow resistance (ΔP)< 3 kPa
Cold-plate surface temp< 52 °C
Proof pressure0.6 MPa
Dimensions (L × W × H)118 × 92.4 × 25 mm

Intel Xeon (Birch Stream) CPU cold plate

Heat dissipation (design-rated)500 W
Cold plate materialCopper C1100
Joining processConfirmed at quotation (DFM review)
Working point40 °C, 1 L/min, 25% EGW
Flow resistance (ΔP)5 kPa
Cold-plate surface temp60 °C
Proof pressure1 MPa
Dimensions (L × W × H)130 × 90 × 25 mm

Designed, engineered and manufactured at the IATF 16949-aligned ToneCooling facility in Huizhou, Guangdong, China; Australian customer engineering support and AS/NZS compliance documentation from Carlton, Victoria.

Product Snapshot · 4 KPI

CPU sockets
2
AMD SP5 LGA6096 · Intel Birch Stream
Reference TDP
350–500 W
per socket · scalable to 600 W
Substrate options
2
Copper · Aluminium
Joining methods
Per programme
confirmed at DFM review

Engineering Reference & Standards

What standards and platform references apply to AMD EPYC SP5 and Intel Birch Stream cold plates?

ToneCooling Australia supplies CPU cold plates for AMD EPYC SP5 (LGA6096) and Intel Birch Stream sockets. Generations supported include AMD Genoa, Bergamo, Genoa-X, Turin (per AMD EPYC platform reference) and Intel Granite Rapids, Sierra Forest (per Intel Xeon Scalable platform reference). Thermal envelope per ASHRAE TC 9.9; AU compliance scope mapped to Standards Australia AS/NZS publications.

Which Australian CPU server programmes does ToneCooling support?

Three Australian CPU programme contexts shape cold plate procurement: AMD-based AI server tier, Intel-based hyperscale tier, and HPC refresh cycles. Each has a different socket footprint, TDP envelope, and CDU integration scope.
Programme · AMD EPYC SP5

Genoa · Bergamo · Genoa-X · Turin generations

AU sovereign cloud and AI cluster builds adopting AMD EPYC SP5. LGA6096 socket, 350–500 W reference TDP, copper or aluminium substrate. Vacuum-brazed or skive-and-bond options.

Programme · Intel Birch Stream

Granite Rapids · Sierra Forest generations

AU hyperscale and Tier-1 colocation deployments adopting Intel Birch Stream platform. ASHRAE W32 / W40 thermal envelope, AS/NZS 60068-2-14 thermal cycling endurance, lot-traceable manufacturing.

Programme · HPC refresh

National research HPC nodes

Australian HPC supercomputing refresh cycles requiring high-density CPU cooling. Direct-to-chip cooling 80–120 kW per rack capable; joining process selected at DFM review for thermal-cycling-critical workloads.

Section 1 of 5

What AMD EPYC SP5 generations are supported?

AMD EPYC SP5 (LGA6096 socket) cold plates support Genoa, Bergamo, Genoa-X, and Turin generations. Reference TDP envelope 400 W per socket; 350–500 W envelope accommodates server-grade SKUs across the family. Available in vacuum-brazed copper (default); the joining process is confirmed per programme at DFM review.
GenerationCodenameReference TDPCold plate process
EPYC 9004 (Genoa)Zen 4 / 96-core280–400 WVacuum braze · per programme
EPYC 9004 (Bergamo)Zen 4c / 128-core300–400 WVacuum braze · per programme
EPYC 9004 (Genoa-X)Zen 4 + 3D V-Cache320–400 WVacuum braze · per programme
EPYC 9005 (Turin)Zen 5350–500 WVacuum braze · per programme

Section 2 of 5

What Intel Birch Stream platforms are supported?

Intel Birch Stream cold plates support Granite Rapids and Sierra Forest CPU configurations. 350–500 W reference TDP envelope. Same joining-process options as the SP5 family.

Section 3 of 5

What CPU TDP envelopes can be cooled?

Standard cold plates handle 350–500 W per socket on 50/50 EGW at 5–8 L/min, ASHRAE W32 inlet (20–32 °C). Higher TDP up to ~ 600 W per socket achievable with custom channel topology and increased flow rate. ΔP envelope 15–25 kPa typical.

Section 4 of 5

Vacuum brazing vs skive-and-bond — which is right?

Vacuum brazing: hyperscaler-grade reliability, helium-leak-tested, suits AI training and sovereign cloud programmes. Skive-and-bond: cost-optimised aluminium variant for volume server programmes where premium bond reliability is not required. The DFM review session covers process selection per programme.
ProcessMaterialCost tierSuits
TLP diffusion bondingCopper C1100PremiumAI training, sovereign cloud, high-cycling
Vacuum brazingCopper C1100StandardHyperscaler grade, established
Skive-and-bondAluminium / copperCost-optimisedVolume server programmes

Section 5 of 5

What AU compliance documentation is provided?

Standard documentation pack: helium leak certificate per cold plate, ultrasonic C-scan report (premium grade), commercial invoice in AUD, packing list, ChAFTA Certificate of Origin (HS 8419 / 8537), material declarations RoHS 2.0. Additional: AS/NZS 60068-2-14 thermal cycling endurance, ISO 9227 salt-spray, PPAP Levels 1–5 on request.

FAQ

What AMD EPYC SP5 generations are supported?

Genoa, Bergamo, Genoa-X (EPYC 9004), Turin (EPYC 9005). Reference TDP 400 W per socket; 350–500 W envelope. Vacuum-brazed copper; joining process confirmed at DFM review.

What Intel Birch Stream platforms are supported?

Granite Rapids and Sierra Forest. 350–500 W TDP. Same process options as SP5.

What CPU TDP envelopes can be cooled?

350–500 W per socket standard; up to ~ 600 W with custom topology. ΔP 15–25 kPa at 5–8 L/min on 50/50 EGW, ASHRAE W32.

Vacuum brazing vs skive-and-bond — which is right?

Vacuum braze for hyperscaler grade; skive-and-bond for cost-optimised volume programmes. DFM review covers process selection.

What AU compliance documentation is provided?

Helium leak cert, C-scan report, AUD commercial invoice, ChAFTA Certificate of Origin, RoHS 2.0 declarations. AS/NZS 60068-2-14, ISO 9227, PPAP 1–5 on request.

Continue Exploring

Related ToneCooling Australia pages

SOLUTION

AI Server Liquid Cooling

AMD EPYC SP5 + Intel Birch Stream cold plates for AU sovereign cloud and HPC programmes.

View solution →
SOLUTION

Data Centre Liquid Cooling

Cold plate kits for AU colocation, sovereign cloud, HPC; CDU-vendor compatible.

View solution →
CAPABILITY

TLP Diffusion Bonding

Premium copper bonding for high-cycling AI training and traction drive workloads.

View capability →
RESOURCE

RFQ Input Checklist

10-field checklist for the fastest path to a Carlton-coordinated engineering response.

View checklist →

Send your CPU cold plate brief

Socket footprint, target TDP, ΔP envelope, programme volume — reviewed by an engineer, with technical review by Huizhou, and answered by email with next steps.

Request a Quote
By ToneCooling Engineering Team · Last updated:

Related CPU cold plates

GB300 4G+2C kitGB200 kitAMD EPYC SP3AMD EPYC SP6Intel Eagle StreamX3 CPUAll GPU cold plates