GPU Cold Plate · NVIDIA H100

NVIDIA H100 Cold Plate Kits for Australia

ToneCooling Australia supplies a complete direct-to-chip liquid cooling assembly for the NVIDIA H100 GPU + NVSwitch baseboard (8 × GPU, 4 × NVSwitch, 6.344 kW validated) deployed in Australian sovereign cloud, HPC and AI inference clusters. Copper GPU and NVSwitch cold plates, integrated flexible hoses and colour-coded quick-disconnect couplings — a ready-to-install kit, not a bare plate. Design, engineering and manufacturing at our own IATF 16949-aligned manufacturing facility in Huizhou, Guangdong, China; AS/NZS documentation, customs coordination and customer engineering support from our Carlton, Victoria team.

6.344 kWtotal validated heat load (8 GPU + 4 NVSwitch)
9 LPMrated system flow rate
40 kPamax pressure drop @ 9 LPM
ToneCooling NVIDIA H100 GPU and NVSwitch liquid cooling assembly, copper cold plates with colour-coded quick disconnects
Copper
GPU + NVSwitch cold plates
1 MPa
max operating pressure
8 + 4
GPU + NVSwitch cold plates in kit
PPAP 1–5
qualification on request

ToneCooling Australia supplies a complete NVIDIA H100 GPU + NVSwitch liquid cooling assembly for Australian AI server and HPC projects — 8 GPU and 4 NVSwitch copper cold plates validated to 6.344 kW total heat load, with integrated hoses and quick-disconnect couplings. Manufacturing is in Huizhou, Guangdong, China.

NVIDIA H100 GPU and NVSwitch liquid cooling assembly, ToneCooling
NVIDIA · H100 · GPU + NVSwitch assembly

H100 GPU + NVSwitch Cooling Assembly

Complete direct-to-chip liquid cooling assembly for the NVIDIA H100 GPU + NVSwitch baseboard, engineered to your baseboard drawing.

Model
T-HS202323
Supported devices
H100 GPU × 8 + NVSwitch × 4
Cold plate material
Copper
Total design heat load
700 W × 8 + 186 W × 4 = 6.344 kW
Cooling medium
Pure water
Inlet coolant temperature
45 °C
Maximum component temperature
below 80 °C
Rated system flow rate
9 LPM
Maximum pressure drop
40 kPa @ 9 LPM
Maximum operating pressure
1 MPa
Overall dimensions (L × W × H)
472.7 × 331 × 130.6 mm
Connection type
Colour-coded quick-disconnect couplings

Frequently asked questions

What NVIDIA H100 cooling configuration do you supply for Australia?

ToneCooling Australia supplies a complete direct-to-chip liquid cooling assembly for the NVIDIA H100 GPU + NVSwitch baseboard — 8 copper GPU cold plates, 4 copper NVSwitch cold plates, integrated flexible hoses and colour-coded quick-disconnect couplings, validated to 6.344 kW total heat load. Design and manufacturing at our IATF 16949-aligned facility in Huizhou; AS/NZS documentation and support from Carlton, Victoria.

Is this a bare cold plate or a complete assembly?

It is a complete, ready-to-install assembly, not a single bare plate — 8 GPU cold plates, 4 NVSwitch cold plates, hose assemblies, quick-disconnect couplings and mounting hardware, engineered to drop into an existing H100 baseboard.

What heat load and flow rate is the H100 assembly validated for?

Validated total heat load is 6.344 kW (700 W × 8 GPU + 186 W × 4 NVSwitch) using pure-water cooling at 45 °C inlet, with hydraulic validation at the rated 9 LPM flow rate and a maximum pressure drop of 40 kPa.

What is the lead time and duty for H100 assemblies into Australia?

Prototype and production lead times are agreed at quotation, door-to-door from Huizhou to Australian capital cities. AU import duty is typically 0–5 % under ChAFTA (HS 8419 / 8537); DDP terms itemise duty, GST and clearance.

Request an H100 assembly quote

Send your baseboard layout, GPU/NVSwitch count, flow and pressure-drop limits. Our Carlton team responds with a DFM review and quotation.

Request a Quote Download the datasheet (PDF)