Resources Hub · 4 Engineering References

Engineering Resources for Australian Buyers

ToneCooling Australia publishes engineering reference content for Australian thermal engineers and procurement leads. The Phase 1 resource library covers four areas: AI server cooling design (direct-to-chip, GB200/H200/SP5/Birch Stream channel topology), BESS cold plate design (cell-to-cell uniformity, AS/NZS 5139 thermal context), AS/NZS standards reference (24+ standards relevant to liquid cooling), and the RFQ input checklist (what to send when requesting a quote).

Request a Quote
Engineering references
4
AI · BESS · AS/NZS · RFQ
AS/NZS standards mapped
24+
across 7 categories
Design guide depth
12 + 14
sections (AI · BESS)
Carlton response
24 h
post-RFQ engineering reply

ToneCooling Australia engineering reference content for AU thermal engineers and procurement leads. AI server cooling design references the NVIDIA GB200 NVL72 platform and the Open Compute Project DC-MHS specification. Thermal-acceptance envelope per ASHRAE TC 9.9 Datacom guideline. AS/NZS standards mapped to Standards Australia publications.

Process & standards glossary (AU engineering reader): TLP = Transient Liquid Phase diffusion bonding · FSW = Friction Stir Welding · CAB = Controlled Atmosphere Brazing · PPAP = Production Part Approval Process · IATF 16949:2016 (international automotive QMS) · ISO 9001:2015 (quality management) · AS/NZS 60068-2-14IEC 60068-2-14:2009 (thermal cycling endurance) · IEC 62619:2017 (industrial battery safety) · AS/NZS 5139:2019 (BESS installation) · AS/NZS 4777.2:2020 (grid-connected inverter).
Page reviewed by ToneCooling Australia Customer Engineering Support Team · Carlton, VIC · Last reviewed: 28 April 2026 · About the team →
5 resources for AU buyers — the ToneCooling Australia master deck (PDF), AI server design guide, BESS design guide, AS/NZS standards reference, and RFQ input checklist. Free download or web-readable. Australian English. Authored by ToneCooling Australia customer engineering support team in collaboration with Huizhou design and engineering team.
COMPARISON

Cold Plate vs Immersion Cooling (BESS)

When liquid cold plates beat immersion for Australian grid-scale BESS — serviceability, AS/NZS 5139, retrofit.

Comparison guideRead the comparison
COMPARISON

Liquid vs Air Cooling (Data Centre)

Why AI GPU racks (80–120 kW) need direct-to-chip liquid cooling — the Australian data-centre buildout.

Comparison guideRead the comparison
PROCESS GUIDE

FSW vs Vacuum Brazed Cold Plate

Joining-process guide — FSW vs vacuum brazing vs TLP, and which suits EV/BESS vs GPU/CPU.

Process guideRead the guide
COMPARISON

Cold Plate vs Heat Sink

Heat dissipation capacity, thermal resistance, space and noise trade-offs — when air cooling stops being enough.

Comparison guideRead the comparison
QUOTATION GUIDE

GB300 Cold Plate Quotation Guide

How Australian AI data-centre buyers get a GB300 copper cold plate quotation — RFQ inputs, AS/NZS support, import logistics.

Quotation guideRead the guide
QUOTATION GUIDE

GB300 4 GPU + 2 CPU Quotation Guide

How Australian buyers get a GB300 4 GPU + 2 CPU Full System copper cold plate quotation — RFQ inputs, AS/NZS support, import logistics.

Quotation guideRead the guide
MASTER DECK

ToneCooling Australia Master Deck

Complete overview for AU engineering & procurement teams — company, four engineering capability pillars, product families, solution areas, AS/NZS compliance and quality. Free PDF download.

10 slides · PDF · Australian EnglishDownload the deck (PDF)
AI Server Cooling Design Guide
DESIGN GUIDE

AI Server Cooling Design Guide

Direct-to-chip cooling for GB200/GB300/H200/SP5/Birch Stream. Channel topology, ΔP budget, manifold integration, CDU compatibility. Free PDF download.

12 sections · ~ 2.8 MB PDF · Australian EnglishRead the guide
BESS Cold Plate Design Guide
DESIGN GUIDE

BESS Cold Plate Design Guide

Cell-to-cell ΔT envelope, channel topology, AS/NZS 5139 thermal context, materials and joining process trade-offs. Free PDF download.

14 sections · ~ 3.2 MB PDF · Australian EnglishRead the guide
AS/NZS Standards Reference
STANDARDS

AS/NZS Standards Reference

24+ AS/NZS / IEC / ISO / EN standards mapped to liquid cooling cold plate design, validation, and AU installation compliance context.

7 categories · 24+ standards mappedView reference
RFQ Input Checklist
CHECKLIST

RFQ Input Checklist

What to send when requesting a quote — TDP map, ΔP, flow rate, qualification scope, AS/NZS context. Accelerate the Carlton-coordinated engineering response.

Technical brief checklistView checklist

What's Inside Each Reference

What engineering depth does each ToneCooling Australia reference cover?

Below is the section-by-section index for each engineering reference, so AU thermal engineers can decide which guide to open first based on their current design stage.
AI Server Cooling Design Guide · 12 sections

Direct-to-chip cooling for GB200/GB300/H200/SP5/Birch Stream

  • NVIDIA GB200 / GB300 / H200 channel topology & Bianca module integration
  • AMD EPYC SP5 (LGA6096) cold plate envelope · Intel Birch Stream socket integration
  • Pressure-drop (ΔP) budget allocation across the rack-level loop
  • Manifold + CDU integration (Vertiv · CoolIT · Stulz · Motivair)
  • Thermal-hydraulic CFD validation methodology · ASHRAE W32 / W40 envelope
  • AS/NZS 60068-2-14 ≡ IEC 60068-2-14:2009 thermal cycling endurance
  • Pawsey / NCI HPC refresh design context · sovereign cloud rack density 80–120 kW
  • RFQ-readiness checkpoints · what to send to accelerate the engineering response
Read the AI server cooling design guide
BESS Cold Plate Design Guide · 14 sections

Grid-scale battery thermal design for Australian programmes

  • Prismatic / pouch / cylindrical cell format trade-offs
  • Cell-to-cell ΔT envelope · TC-1P104S real-data baseline (6.2 °C / 104 cells)
  • Channel topology · flow uniformity · stamped-brazed AL3003MOD construction
  • CFD methodology · 50/50 EGW coolant baseline
  • AS/NZS 5139:2019 thermal context · BESS installation interface
  • AS/NZS 4777.2:2020 inverter integration thermal envelope
  • IEC 62619:2017 industrial battery safety implications for cold plate design
  • Materials & joining trade-offs (TLP · CAB · FSW · vacuum braze)
  • PFAS-free coolant compatibility · EN 17681-1:2022 SGS-certified scope
  • PPAP Levels 1–5 readiness · AEMO ISP / CIS programme alignment
Read the BESS cold plate design guide
AS/NZS Standards Reference · 24+ standards

Standards mapped across 7 categories for AU liquid cooling

  • Cat 1 · BESS installation: AS/NZS 5139:2019, IEC 62619:2017
  • Cat 2 · Grid-connected inverter: AS/NZS 4777.2:2020
  • Cat 3 · Thermal cycling endurance: AS/NZS 60068-2-14 ≡ IEC 60068-2-14:2009
  • Cat 4 · IP enclosure code: AS/NZS 60529
  • Cat 5 · Salt-spray corrosion: ISO 9227 (AU coastal context)
  • Cat 6 · Materials & substances: RoHS 2.0, PFAS-free per EN 17681-1:2022 SGS
  • Cat 7 · QMS & manufacturing: ISO 9001:2015, IATF 16949:2016
View AS/NZS standards reference
RFQ Input Checklist · technical brief

What to send to accelerate the Carlton-coordinated response

  • Application + platform (GB200 / SP5 / TC-1P104S BESS module / IGBT inverter)
  • TDP map per platform (W per die or W per cell)
  • Target ΔP and coolant flow rate
  • Coolant chemistry (50/50 EGW · 25 % PG · DI water)
  • Inlet temperature window (ASHRAE W32 / W40)
  • CDU model (for AI server) or BMS pump curve (for BESS)
  • Lead-time requirement & programme schedule
  • Qualification scope · PPAP level if applicable
  • Mechanical envelope drawing or CAD (STEP / IGES)
View the RFQ input checklist

Which engineering reference helps your Australian RFQ?

Engineering reference content is free; an RFQ gets a Carlton-coordinated 24-hour response with technical review by Huizhou.

Request a Quote