GPU Cold Plate · NVIDIA GB200

NVIDIA GB200 Cold Plate Kits for Australia

ToneCooling Australia supplies direct-to-chip cold plate kits for the NVIDIA GB200 Grace Blackwell Bianca module (2,700 W), manifold-ready for NVL72 rack-scale AI deployments. T2 copper micro-channel cold plates, nitrogen-protected brazing + laser welding, 0.6 MPa working pressure, 100 % helium-leak and ultrasonic C-scan tested. Manufactured at our IATF 16949-aligned facility in Huizhou, Guangdong, China; AS/NZS documentation and engineering support from Carlton, Victoria.

2,700 Wper Bianca module
NVL72rack-ready architecture
2.5 L/minat 35 ± 5 kPa (tested)
ToneCooling NVIDIA GB200 Bianca cold plate kit, brazed T2 copper micro-channel
T2 copper
brazed + laser-welded cold plate
≤ 1×10⁻⁹
mbar·L/s helium leak (100 %)
0.6 MPa
working pressure
PPAP 1–5
qualification on request

ToneCooling Australia manufactures NVIDIA GB200 direct-to-chip liquid cold plates for Australian AI data centres — 2,700 W per Bianca module, T2 copper micro-channel, nitrogen-protected brazing + laser welding, 2.5 L/min at 35 ± 5 kPa in batch validation, NVL72 manifold-ready, 100 % leak verified. Manufacturing is in Huizhou, Guangdong, China.

NVIDIA GB200 Bianca cold plate top view, ToneCooling
NVIDIA · Bianca module · Grace Blackwell

GB200 GPU Cold Plate Kit

Direct-to-chip cold plate kit for the NVIDIA GB200 Bianca module, NVL72-ready.

Thermal envelope (per Bianca module)
2,700 W (1,200 + 1,200 + 300 W)
Cold plate material
T2 copper
Joining process
Nitrogen-protected brazing + laser welding
Channel topology
Micro-channel fin, 0.4–0.8 mm width, 1.5–3.0 mm depth
Flow rate (tested)
2.5 L/min, pure water, 25 ± 2 °C inlet
Pressure drop (tested)
35 ± 5 kPa at 2.5 L/min
Cold plate surface temperature
Below 43 °C (datasheet test condition)
Dimensions
235 × 190 × 30 mm
Coolant compatibility
50/50 EGW · PG25 · ASHRAE W40 design
Inlet temperature window
20–40 °C (ASHRAE W40-aligned)
Working pressure
0.6 MPa
Burst pressure
≥ 4 MPa (lot-sample tested)
Quick-disconnect
Dry-break couplings, specified per CDU and manifold
Manifold compatibility
OCP DC-MHS r1.0 / r1.1 pitch
Helium leak rate
≤ 1×10⁻⁹ mbar·L/s (100 % of units)
Bond verification
Ultrasonic C-scan, 100 %
NVL72 rack support
Yes — manifold-ready

GB200 cold plate datasheet and Australian reference

Download the GB200 datasheet (PDF)

Part No. TC-BZP-GB200-01A, Rev A. Heat load, material, joining process, flow rate, pressure drop, working pressure and dimensions, issued by ToneCooling Australia Pty Ltd.

PDF · 1.6 MB

Victoria, 2026: GB300-class systems

An Australian advanced-engineering company in Victoria ordered several ToneCooling GB300-class liquid cold plate systems for liquid cooling evaluation. Test data from the GB300-class datasheet programme is available on request.

Australian reference

Frequently asked questions

What is the AU lead time and duty for GB200 cold plates?

Prototype and production lead times are agreed at quotation, door-to-door from Huizhou to Australian capitals. AU import duty is typically 0–5 % under ChAFTA (HS 8419 / 8537); DDP itemises duty, GST and clearance.

Does the GB200 cold plate support NVL72 racks?

Yes. The GB200 Bianca cold plate is manifold-ready for NVL72 rack-scale deployment, OCP DC-MHS manifold pitch, dry-break quick-disconnects.

How is GB200 cold plate quality verified?

Every production unit is helium-leak tested to ≤ 1×10⁻⁹ mbar·L/s and 100 % ultrasonic C-scan inspected. Batch validation at 25 ± 2 °C pure-water inlet and 2.5 L/min gives a 35 ± 5 kPa pressure drop with the cold plate surface below 43 °C. Leak, pressure-holding and pressure-drop records and PPAP 1–5 are available on request.

Is there a GB200 cold plate datasheet?

Yes. The ToneCooling Australia datasheet for part TC-BZP-GB200-01A (Rev A) lists heat load (1,200 + 1,200 + 300 W), T2 copper, nitrogen-protected brazing + laser welding, 2.5 L/min, 35 ± 5 kPa, 0.6 MPa and 235 × 190 × 30 mm. Download the PDF.

Where are GB200 cold plates made and supported?

Designed and manufactured at our IATF 16949-aligned facility in Huizhou, Guangdong, China; AS/NZS documentation and engineering support from Carlton, Victoria.

Request a GB200 cold plate quote

Send your module/rack layout, CDU details, flow and pressure-drop limits. Our Carlton team responds with a DFM review and quotation.

Request a Quote