Liquid Cooling Solutions for Australian Industry
ToneCooling Australia organises its work around 5 solution areas relevant to Australian engineering: AI server liquid cooling, data centre liquid cooling, BESS energy storage, power electronics cooling, and industrial cold plates. Each area has distinct thermal physics, regulatory framing, and integration constraints — landing on the right solution page lets your engineering and procurement team have the right design conversation in one click. Cold plates are designed, engineered & manufactured at our IATF 16949-aligned partner facility in Huizhou, with AS/NZS compliance support from Carlton VIC.
Request a QuoteLiquid cooling solutions for Australian engineering teams — direct-to-chip cold plate kits aligned to the NVIDIA GB200 NVL72 platform, the Open Compute Project DC-MHS specification, and the ASHRAE TC 9.9 Datacom guideline. AS/NZS scope per Standards Australia.
AI Server Liquid Cooling
Direct-to-chip cold plate kits for NVIDIA GB200, GB300, H200, AMD EPYC SP5, Intel Birch Stream — five AI server platforms most deployed in AU sovereign cloud, Pawsey/NCI HPC, and edge AI.
Explore solution
Data Centre Liquid Cooling
Cold plate kits for AU colocation, sovereign cloud, and HPC refresh deployments. CDU-vendor compatible — Vertiv, CoolIT, Stulz, Motivair. Rack power density 80–120 kW+ supported.
Explore solution
BESS Energy Storage
Liquid cooling cold plates for Australian grid-scale battery energy storage. TC-1P104S real test data: 4 Pa air-tightness leak, 21.2 kPa ΔP, 6.2 °C cell-top ΔT. PFAS-free SGS-certified, AS/NZS 5139 design-aware.
Explore solution
Power Electronics Cooling
IGBT and SiC module cold plates for grid-forming inverters, traction drives, and PCS power electronics. AS/NZS 4777.2 PCS context-aware. Supports Infineon, Semikron, Mitsubishi, Fuji module footprints.
Explore solution
Industrial Cold Plates
Custom cold plates for fibre and CO₂ laser sources, medical imaging gradient coils, factory automation drives, semiconductor process tools, and welding equipment.
Explore solutionHow does each solution area's thermal envelope compare?
| Solution | Heat source / cell load | Cold plate ΔP envelope | Joining process | Prototype lead time |
|---|---|---|---|---|
| AI Server | 700–2,700 W per die | 18.5–35 kPa | TLP / vacuum braze | Agreed at quotation |
| Data Centre | 80–120 kW per rack | 25–45 kPa rack-level | TLP / vacuum braze | Agreed at quotation |
| BESS | 15 W per cell × 104 | 15–25 kPa | CAB stamped-brazed | Agreed at quotation |
| Power Electronics | 3–25 kW per module | 10–20 kPa | FSW / CAB | Agreed at quotation |
| Industrial | 100 W–10 kW (varies) | 5–25 kPa (varies) | Per-application | Agreed at quotation |
Australian liquid cooling solutions FAQ
Which Australian industries does ToneCooling Australia serve?
5 solution areas: AI server liquid cooling (NVIDIA GB200/GB300/H200, AMD SP5, Intel Birch Stream), data centre liquid cooling (sovereign cloud, Pawsey/NCI HPC, colocation), BESS (TC-1P104S reference, AEMO ISP-aligned), power electronics (IGBT, SiC, grid-forming PCS), industrial (laser, medical imaging, robotics, semiconductor).
What primary platforms are supported across solutions?
AI server: NVIDIA GB200/GB300/H200, AMD EPYC SP5, Intel Birch Stream. BESS: TC-1P104S. Power electronics: IGBT/SiC modules from Infineon, Semikron, Mitsubishi, Fuji. Industrial: IPG/Coherent/Trumpf laser, Siemens/GE/Philips medical imaging, ABB/Festo/FANUC automation.
How does BESS cooling differ from AI server cooling?
AI server: high-heat-flux per area (700–2,700 W concentrated on small die), narrow ΔT, tight CDU pressure, copper micro-channel topology. BESS: low flux distributed across many cells (15 W × 104), broader ΔT, looser pressure, stamped-brazed aluminium plates. Both validate to helium leak ≤ 1×10⁻⁹ mbar·L/s.
What custom programmes are accepted?
Custom programmes accepted across all 5 solution areas. Low-MOQ, as agreed at quotation (AI server) or as agreed at quotation (BESS / power electronics / industrial) lead time. PPAP Levels 1–5 supported. Cold plate design and engineering at Huizhou; AS/NZS compliance support from Carlton VIC.
Which liquid cooling solution fits your Australian programme?
Click into a solution page, or send your RFQ now and the Carlton VIC team will route to the correct Huizhou engineering team.