Solutions Hub · 5 Solution Areas
Liquid Cooling Solutions for Australian Industry
ToneCooling Australia organises its work around 5 solution areas relevant to Australian engineering: AI server liquid cooling, data centre liquid cooling, BESS energy storage, power electronics cooling, and industrial cold plates. Each area has distinct thermal physics, regulatory framing, and integration constraints — landing on the right solution page lets your engineering and procurement team have the right design conversation in one click. Cold plates are designed, engineered & manufactured at our own IATF 16949-aligned manufacturing facility in Huizhou, with AS/NZS compliance support from Carlton VIC.
Request a QuoteLiquid cooling solutions for Australian engineering teams — direct-to-chip cold plate kits aligned to the NVIDIA GB200 NVL72 platform, the Open Compute Project DC-MHS specification, and the ASHRAE TC 9.9 Datacom guideline. AS/NZS scope per Standards Australia.
AI Server Liquid Cooling
Direct-to-chip cold plate kits for NVIDIA GB200, GB300, H200, AMD EPYC SP5, Intel Birch Stream — five AI server platforms most deployed in AU sovereign cloud, national research HPC, and edge AI.
Explore solution
Data Centre Liquid Cooling
Cold plate kits for AU colocation, sovereign cloud, and HPC refresh deployments. CDU-vendor compatible — major rack-level CDU platforms. High rack power densities supported.
Explore solution
BESS Energy Storage
Liquid cooling cold plates for Australian grid-scale battery energy storage. TC-1P104S real test data: 4 Pa air-tightness leak, 21.2 kPa ΔP, 6.2 °C cell-top ΔT. PFAS-free SGS-certified, AS/NZS 5139 design-aware.
Explore solution
Power Electronics Cooling
IGBT and SiC module cold plates for grid-forming inverters, traction drives, and PCS power electronics. AS/NZS 4777.2 PCS context-aware. Supports standard and custom IGBT/SiC module footprints.
Explore solution
Industrial Cold Plates
Custom cold plates for fibre and CO₂ laser sources, medical imaging gradient coils, factory automation drives, semiconductor process tools, and welding equipment.
Explore solutionHow does each solution area's thermal envelope compare?
| Solution | Heat source / cell load | Cold plate ΔP envelope | Joining process | Prototype lead time |
|---|---|---|---|---|
| AI Server | 700–2,700 W per die | 18.5–35 kPa | Per programme | Agreed at quotation |
| Data Centre | high-density racks | 25–45 kPa rack-level | Per programme | Agreed at quotation |
| BESS | 15 W per cell × 104 | 15–25 kPa | CAB stamped-brazed | Agreed at quotation |
| Power Electronics | 3–25 kW per module | 10–20 kPa | FSW / CAB | Agreed at quotation |
| Industrial | 100 W–10 kW (varies) | 5–25 kPa (varies) | Per-application | Agreed at quotation |
Australian liquid cooling solutions FAQ
Which Australian industries does ToneCooling Australia serve?
5 solution areas: AI server liquid cooling (NVIDIA GB200/GB300/H200, AMD SP5, Intel Birch Stream), data centre liquid cooling (sovereign cloud, national research HPC, colocation), BESS (TC-1P104S reference, AEMO ISP-aligned), power electronics (IGBT, SiC, grid-forming PCS), industrial (laser, medical imaging, robotics, semiconductor).
What primary platforms are supported across solutions?
AI server: NVIDIA GB200/GB300/H200, AMD EPYC SP5, Intel Birch Stream. BESS: TC-1P104S. Power electronics: standard IGBT/SiC module footprints. Industrial: IPG/Coherent/Trumpf laser, Siemens/GE/Philips medical imaging, ABB/Festo/FANUC automation.
How does BESS cooling differ from AI server cooling?
AI server: high-heat-flux per area (700–2,700 W concentrated on small die), narrow ΔT, tight CDU pressure, copper micro-channel topology. BESS: low flux distributed across many cells (15 W × 104), broader ΔT, looser pressure, stamped-brazed aluminium plates. Both validate to helium leak ≤ 1×10⁻⁹ mbar·L/s.
What custom programmes are accepted?
Custom programmes accepted across all 5 solution areas. Low-MOQ, as agreed at quotation (AI server) or as agreed at quotation (BESS / power electronics / industrial) lead time. PPAP Levels 1–5 supported. Cold plate design and engineering at Huizhou; AS/NZS compliance support from Carlton VIC.
Which liquid cooling solution fits your Australian programme?
Click into a solution page, or send your RFQ now and the Carlton VIC team will route to the correct Huizhou engineering team.
Request a Quote