Solution · Data Centre · Perth WA

Data Centre Liquid Cooling for Perth

ToneCooling Australia supplies direct-to-chip cold plates and rack-level liquid-cooling hardware for Perth AI and hyperscale data centres. Support for NVIDIA GB200 / GB300 / H200 and AMD EPYC SP5, copper micro-channel cold plates rated to roughly 80–120 kW per rack. Manufacturing at our IATF 16949-aligned facility in Huizhou, Guangdong, China; AS/NZS documentation, customs coordination and engineering support from Carlton, Victoria.

80–120 kWper rack with liquid cooling
GB200/GB300/H200NVIDIA platforms supported
AS/NZSaligned documentation
ToneCooling rack-level direct-to-chip liquid cooling kit for Perth data centres
8–25 kW
air cooling per rack
80–120 kW
liquid cooling per rack
≤ 1×10⁻⁹
mbar·L/s helium leak
Carlton VIC
engineering support

ToneCooling Australia supplies direct-to-chip liquid cooling cold plates for Perth data centres, supporting NVIDIA GB200/GB300/H200 and AMD EPYC SP5 at roughly 80–120 kW per rack. Manufacturing is in Huizhou, Guangdong, China; support from Carlton, Victoria.

Liquid cold plate thermal validation for Perth data centre deployment, ToneCooling
Perth data centre · direct-to-chip

Liquid cooling capability for Perth DCs

Rack-level direct-to-chip cooling for high-density AI deployments in Perth facilities.

Rack density (liquid)
~80–120 kW per rack
Rack density (air, reference)
~8–25 kW per rack
NVIDIA platforms
GB200 (2,700 W) · GB300 4G+2C (tested) · H200 (8 × 700 W)
AMD platform
EPYC SP5
Cold plate material
Copper C1100 micro-channel
Joining process
Confirmed per programme at DFM review
Coolant / loop
50/50 EGW · ASHRAE W40-aligned
Quality
100 % helium-leak + ultrasonic C-scan
Compliance / support
AS/NZS docs, coordinated from Carlton VIC

Perth / WA context

Perth and Western Australia host data-centre capacity serving mining, resources and government workloads. Liquid cooling enables high-density AI compute within existing power envelopes. ToneCooling Australia provides the cold-plate and manifold hardware with engineering support timed to local project schedules. See also national data centre cooling, Sydney and Melbourne.

Frequently asked questions

Do you supply liquid cooling cold plates for Perth data centres?

Yes. ToneCooling Australia supplies direct-to-chip cold plates and rack-level cooling hardware for Perth AI and hyperscale data centres, supporting NVIDIA GB200/GB300/H200 and AMD EPYC SP5. Manufacturing in Huizhou, China; AS/NZS documentation and engineering support from Carlton, Victoria.

How much rack density can liquid cooling support in Perth?

Direct-to-chip liquid cooling supports approximately 80–120 kW per rack, versus roughly 8–25 kW for air cooling — enabling high-density AI clusters within existing facility footprints and power envelopes.

Which platforms do you cool?

NVIDIA GB200 (2,700 W/module), GB300 (4 GPU + 2 CPU kit, tested datasheet), H200 (8 × 700 W) and AMD EPYC SP5, with copper micro-channel cold plates and 100 % helium-leak and C-scan testing.

What compliance applies?

Cooling hardware is supplied with AS/NZS-aligned documentation; coolant loops follow ASHRAE W40 design. ToneCooling Australia Pty Ltd (ABN 96 653 174 040) coordinates compliance from Carlton, Victoria for WA projects.

Discuss a Perth data centre cooling project

Send rack layout, target density, platforms and coolant loop. Our Carlton team responds with a thermal review and quotation.

Request a Quote
By ToneCooling Engineering Team · Last updated: