Solution · Data Centre · Sydney NSW
Data Centre Liquid Cooling for Sydney
Data centre liquid cooling in Sydney means removing GPU and CPU heat with cold plates and a closed coolant loop instead of room air. ToneCooling Australia supplies the direct-to-chip cold plates and rack-level hardware for Sydney AI and hyperscale data centres — standard GB300 4G+2C, GB200, H200 and H100 kits supplied to their datasheets, plus custom cold plates for other platforms. Cold plates are made in our own manufacturing facility in Huizhou, China (IATF 16949-aligned); engineering coordination and documentation come from Carlton, Victoria.

What does ToneCooling supply for data centre liquid cooling in Sydney?
ToneCooling Australia supplies direct-to-chip liquid cooling cold plates for Sydney data centres: standard kits for NVIDIA GB300 4G+2C, GB200, H200 and H100 supplied to their datasheets, and custom cold plates for other platforms such as AMD EPYC SP5. Cold plates are made in our own manufacturing facility in Huizhou, China; engineering support is delivered from Carlton, Victoria.

Liquid cooling capability for Sydney DCs
Rack-level direct-to-chip cooling for high-density AI deployments in Sydney facilities.
| Item | Specification |
|---|---|
| NVIDIA platforms | GB300 4G+2C (TC-BZP-GB300-01A) · GB200 (TC-BZP-GB200-01A, 1,200 + 1,200 + 300 W) · H200 / H100 assemblies (8 GPU + 4 NVSwitch) |
| AMD platform | EPYC SP5 (custom design) |
| Cold plate material | Copper micro-channel (GB200 kit: T2 copper, per datasheet) |
| Joining process | Confirmed at quotation (DFM review); GB200 kit: nitrogen-protected brazing + laser welding |
| Coolant / loop | 50/50 EGW · ASHRAE W40-aligned |
| Quality | 100 % helium leak test (criterion set per project); thermal resistance, leak and flatness test reports available |
| Datasheets | GB300, GB200, H200 and H100 datasheets download directly from this page, no form |
| Samples and lead time | Custom samples are available from a single piece. Prototypes typically 4–6 weeks including design and simulation; production normally 6–8 weeks, confirmed at quotation |
| Compliance | AS/NZS-aligned documentation, coordinated from Carlton VIC; CDU electrical safety pathway confirmed per project at quotation |
What should a Sydney data centre plan for with liquid cooling?
A Sydney AI data centre should plan direct-to-chip cold plates on GPUs and CPUs, a closed warm-water loop, and heat rejection sized for Western Sydney summer peaks. ToneCooling Australia supplies standard GB300 4G+2C and GB200 cold plate kits with downloadable datasheets, and custom cold plates for other platforms.
Direct-to-chip liquid cooling lets Sydney operators raise rack density within an existing hall, because heat leaves through the coolant loop rather than room air. See also data centre liquid cooling equipment in Australia, AI server rack cold plates and liquid vs air cooling.
- Summer peaks
- Penrith Lakes recorded 48.9 °C on 4 January 2020, the highest temperature on record in the Sydney basin (Bureau of Meteorology). Size dry coolers and CDUs for the peak ambient, not the average.
- Loop temperature
- Warm-water supply (ASHRAE W32–W40 classes) keeps heat rejection possible on hot days and cuts chiller hours.
- Water
- Closed-loop cold plates recirculate coolant; see data centre water use and liquid cooling.
- Pressure budget
- Match cold plate pressure drop to the CDU: GB200 kit 35 ± 5 kPa at 2.5 L/min; GB300 GPU plate 12.06 kPa at 1.7 L/min (datasheets).
Standard kits for Sydney AI projects
GB300 4G+2C cold plate kit
4 GPU + 2 CPU cold plates (TC-BZP-GB300-01A). Tested: GPU plate 0.0130–0.0133 °C/W at 1066.94 W, 1.7 L/min, 12.06 kPa; CPU plate 0.0220 °C/W at 485.46 W.
GB200 cold plate kit
TC-BZP-GB200-01A for 1,200 + 1,200 + 300 W. T2 copper, nitrogen-protected brazing + laser welding; 2.5 L/min, 35 ± 5 kPa, 0.6 MPa.
H200 liquid cooling assembly
8 GPU + 4 NVSwitch, 6.344 kW total heat load; 10 LPM recommended flow, 40 kPa maximum pressure drop, 1 MPa.
H100 liquid cooling assembly
8 GPU + 4 NVSwitch, 6.344 kW total heat load; 9 LPM, 40 kPa maximum pressure drop, 1 MPa.
These four are standard kits supplied to their datasheets. Cold plates for other GPU and CPU platforms are custom-built and quoted per programme.
How do you choose a liquid cooling supplier for a Sydney data centre?
Choose a supplier that shows tested data for your exact platform, lets you download the datasheet without a form, states what it makes in-house and what it sources, and leak-tests every cold plate. For Sydney sites, also check that the cold plate pressure drop and supply temperature fit your CDU and your heat rejection on Western Sydney peak days.
| Check | What to ask for | What ToneCooling Australia provides |
|---|---|---|
| Tested data for your platform | Thermal resistance, flow and pressure drop, with test conditions | GB300 GPU plate: 0.0130–0.0133 °C/W at 1,066.94 W, 1.7 L/min, 12.06 kPa (pure water, 2026-03-20 test). GB200 kit: 2.5 L/min, 35 ± 5 kPa (datasheet) |
| Datasheet access | Download without a form | GB300, GB200, H200 and H100 datasheets download from this page |
| Manufacturing scope | What is made in-house and what is sourced | Cold plates: our own manufacturing facility in Huizhou, China (IATF 16949-aligned). CDUs, manifolds and quick disconnects: supplied by ToneCooling from China, configured to order |
| Leak and quality testing | Leak test on every unit, and test reports | 100 % helium leak test (criterion set per project); thermal resistance, leak and flatness reports available |
| Hydraulic fit | Pressure drop at your flow versus CDU pump head | Per-plate values in each datasheet; CDU and manifold sized per project |
| Electrical safety (CDUs) | Pathway for powered equipment in NSW | Electrical safety pathway is confirmed per project at quotation |
| Samples before volume | First articles for your own testing | Custom samples are available from a single piece; prototypes typically 4–6 weeks including design and simulation |
| Local entity | Who quotes, contracts and supports | ToneCooling Australia Pty Ltd, ABN 96 653 174 040, Carlton VIC; New Zealand projects are handled by the same entity |
An engineer reviews every RFQ and replies by email with next steps. Send an RFQ RFQ checklist
Frequently asked questions
Do you supply liquid cooling cold plates for Sydney data centres?
Yes. ToneCooling Australia supplies direct-to-chip cold plates and rack-level cooling hardware for Sydney AI and hyperscale data centres, supporting NVIDIA GB200 / GB300 / H200 / H100 and AMD EPYC SP5 platforms. Cold plates are made in our own manufacturing facility in Huizhou, China; documentation, customs and engineering support come from Carlton, Victoria.
Who provides liquid cooling for data centres in Sydney?
Data centre operators provide liquid-ready halls; equipment suppliers provide the cooling hardware. ToneCooling Australia supplies direct-to-chip cold plates, manifolds and rack-level liquid cooling hardware for Sydney projects, working with the operator or integrator that runs the site.
How much heat can a GB300 or GB200 cold plate kit remove?
Per the datasheets, the GB300 4G+2C GPU plate was tested at 1,066.94 W with 1.7 L/min pure water (0.0130–0.0133 °C/W, 12.06 kPa) and the CPU plate at 485.46 W; the GB200 kit is rated for 1,200 + 1,200 + 300 W at 2.5 L/min and 35 ± 5 kPa. Rack totals depend on your tray count and are confirmed in the thermal review.
Which platforms do you cool for Sydney AI deployments?
NVIDIA GB200 (1,200 + 1,200 + 300 W per kit), GB300 (4 GPU + 2 CPU kit with a tested datasheet), H200 and H100 (8 GPU + 4 NVSwitch assemblies), and AMD EPYC SP5 as a custom design. Every cold plate is 100 % helium leak tested; the acceptance criterion is set per project.
What is liquid cooling in data centres?
Liquid cooling in data centres moves heat from processors into a coolant instead of air. In direct-to-chip cooling, a cold plate sits on each GPU or CPU and a closed loop carries the heat to a coolant distribution unit (CDU) and then to dry coolers or a facility water loop.
How do Western Sydney summer temperatures affect liquid cooling design?
Heat rejection must work on the hottest days. Penrith Lakes recorded 48.9 °C in January 2020 (Bureau of Meteorology), so dry coolers and CDUs should be sized for peak ambient, and a warm-water supply temperature keeps the loop within its design envelope.
Are data centres still using water for cooling?
Many still use water for heat rejection. Closed-loop direct-to-chip cold plates recirculate the same coolant, so site water use depends mainly on the heat-rejection choice: dry coolers use little or no water, while evaporative cooling towers use more. See data centre water use and liquid cooling.
How much does data centre liquid cooling cost in Sydney?
Each project is quoted by configuration — platform, number of racks, CDU and heat rejection. Send an RFQ with your rack layout, heat load per chip and coolant loop; an engineer reviews every RFQ and replies by email with next steps.
What compliance applies to data centre cooling hardware in NSW?
Cooling hardware is supplied with AS/NZS-aligned documentation; coolant loops follow ASHRAE W40 design. For CDUs and other powered equipment, the electrical safety pathway is confirmed per project at quotation. ToneCooling Australia Pty Ltd is an Australian entity (ABN 96 653 174 040) coordinating from Carlton, Victoria.
Discuss a Sydney data centre cooling project
Send rack layout, platforms, heat load per chip and coolant loop. Custom samples are available from a single piece. An engineer reviews every RFQ and replies by email with next steps.
Request a QuoteSources and standards referenced: Bureau of Meteorology, NSW January 2020 climate summary · ASHRAE TC 9.9 Datacom Series · Open Compute Project, Cooling Environments · ToneCooling Australia datasheets TC-BZP-GB300-01A and TC-BZP-GB200-01A.