Solution · Data Centre · Brisbane QLD

Data Centre Liquid Cooling for Brisbane

ToneCooling Australia supplies direct-to-chip cold plates and rack-level liquid-cooling hardware for Brisbane AI and hyperscale data centres. Support for NVIDIA GB200 / GB300 / H200 and AMD EPYC SP5, copper micro-channel cold plates rated to roughly 80–120 kW per rack. Manufacturing at our IATF 16949-aligned facility in Huizhou, Guangdong, China; AS/NZS documentation, customs coordination and engineering support from Carlton, Victoria.

80–120 kWper rack with liquid cooling
GB200/GB300/H200NVIDIA platforms supported
AS/NZSaligned documentation
ToneCooling rack-level direct-to-chip liquid cooling kit for Brisbane data centres
8–25 kW
air cooling per rack
80–120 kW
liquid cooling per rack
≤ 1×10⁻⁹
mbar·L/s helium leak
Carlton VIC
engineering support

ToneCooling Australia supplies direct-to-chip liquid cooling cold plates for Brisbane data centres, supporting NVIDIA GB200/GB300/H200 and AMD EPYC SP5 at roughly 80–120 kW per rack. Manufacturing is in Huizhou, Guangdong, China; support from Carlton, Victoria.

Liquid cold plate thermal validation for Brisbane data centre deployment, ToneCooling
Brisbane data centre · direct-to-chip

Liquid cooling capability for Brisbane DCs

Rack-level direct-to-chip cooling for high-density AI deployments in Brisbane facilities.

Rack density (liquid)
~80–120 kW per rack
Rack density (air, reference)
~8–25 kW per rack
NVIDIA platforms
GB200 (2,700 W) · GB300 4G+2C (tested) · H200 (8 × 700 W)
AMD platform
EPYC SP5
Cold plate material
Copper C1100 micro-channel
Joining process
Confirmed per programme at DFM review
Coolant / loop
50/50 EGW · ASHRAE W40-aligned
Quality
100 % helium-leak + ultrasonic C-scan
Compliance / support
AS/NZS docs, coordinated from Carlton VIC

Brisbane / QLD context

Brisbane and South-East Queensland are a growing edge and cloud data-centre region. Direct-to-chip liquid cooling lets operators lift rack density without expanding facility footprint or power. ToneCooling Australia provides the cold-plate and manifold hardware with engineering support timed to local project schedules. See also national data centre cooling, Sydney and Melbourne.

Frequently asked questions

Do you supply liquid cooling cold plates for Brisbane data centres?

Yes. ToneCooling Australia supplies direct-to-chip cold plates and rack-level cooling hardware for Brisbane AI and hyperscale data centres, supporting NVIDIA GB200/GB300/H200 and AMD EPYC SP5. Manufacturing in Huizhou, China; AS/NZS documentation and engineering support from Carlton, Victoria.

How much rack density can liquid cooling support in Brisbane?

Direct-to-chip liquid cooling supports approximately 80–120 kW per rack, versus roughly 8–25 kW for air cooling — enabling high-density AI clusters within existing facility footprints and power envelopes.

Which platforms do you cool?

NVIDIA GB200 (2,700 W/module), GB300 (4 GPU + 2 CPU kit, tested datasheet), H200 (8 × 700 W) and AMD EPYC SP5, with copper micro-channel cold plates and 100 % helium-leak and C-scan testing.

What compliance applies?

Cooling hardware is supplied with AS/NZS-aligned documentation; coolant loops follow ASHRAE W40 design. ToneCooling Australia Pty Ltd (ABN 96 653 174 040) coordinates compliance from Carlton, Victoria for QLD projects.

Discuss a Brisbane data centre cooling project

Send rack layout, target density, platforms and coolant loop. Our Carlton team responds with a thermal review and quotation.

Request a Quote