Equipment selection · Australia & New Zealand

TC-IPS-1000: Integrated Pump Skid

Specify TC-IPS-1000 pump-skid circulation for an AU/NZ cooling loop with a documented pressure budget, fluid mixture and heat balance. The catalogue envelope is 2200 × 1400 × 2000 mm.

Integrated Pump Skid series reference, not an exact TC-IPS-1000 configuration
Series reference image only. Confirm the model configuration, dimensions, connections and accessories against the controlled drawing.

Selection in brief

TC-IPS-1000 lists a 1000 kW loop-duty reference, 3200 L/min flow and a 5°C loop temperature-rise reference. These catalogue fields are selection inputs, not independent confirmation of one simultaneous duty point. Request a heat balance using the actual fluid properties and operating temperatures.

Reconcile flow and temperature rise at one operating point

Do not transfer the 6.5°C temperature-rise reference from the larger IPS models into the IPS-1000 selection. Calculate the required mass flow from the project heat duty, then convert to volume flow using fluid density at the agreed operating temperature. This is especially relevant when a glycol mixture changes heat capacity and viscosity.

The DN200 connection and 35 m head entries do not establish how much pressure remains for external pipework. List the cooler, heat exchanger, valves, filter condition and connecting pipe lengths. Request a clear split between internal skid losses and available differential pressure at the external interfaces.

TC-IPS-1000 catalogue reference values

ParameterCatalogue reference
ModelTC-IPS-1000
Equipment typeIntegrated Pump Skid
Catalogue loop-duty reference1000 kW
Flow reference3200 L/min
Flow adjustment range40–100%
Head reference — confirm at required flow35 m
Power consumption reference< 32 kW
Catalogue electrical supply3-ph AC 380 V 50/60 Hz or 480 V 60 Hz
External dimensions2200 × 1400 × 2000 mm
Catalogue mass1050 kg
Pump arrangement1+1
Connection nominal size — standard to confirmDN200
Filtration reference50 μm
ConditionReference / action
Loop temperature-rise reference5 ℃
Heat rejectionProvided by separate system equipment
Fluid propertiesConfirm concentration, density, heat capacity and viscosity

Source: the linked ToneCooling TC-IPS-1000 model datasheet, as transcribed in the supplied catalogue material. Values are not independently verified performance or a guarantee that all fields apply at one simultaneous operating point. Confirm the document revision, fluid, temperatures, measurement boundaries, dimension orientation and mass basis in the accepted selection.

TC-IPS-1000 versus TC-IPS-600: what to compare

IPS-1000 lists 3200 L/min and DN200; IPS-600 lists 2000 L/min and DN150. Both list a 5°C loop temperature-rise reference. A smaller connected loop needs a check of minimum flow and interface losses, not a capacity-only substitution.

Comparison uses the catalogue references listed on the pump skid series page and its linked model datasheets. Figures are not a project performance guarantee. Confirm controlled document revisions before procurement.

Free model datasheet

TC-IPS-1000

Use this model-specific PDF for initial comparison. Request the controlled drawing and configuration-specific duty confirmation for procurement.

Download TC-IPS-1000 PDF

Free PDF · no form required. The series photograph is not a certified arrangement drawing.

Agree the supply and acceptance scope

List the equipment, connections, controls, sensors and accessories included in the offer. Assign installation, flushing, filling, electrical connection and commissioning to named project parties. Local enquiry support does not imply local stock, an included service contract or on-site installation.

Request the offered electrical schedule and applicable conformity documents for your Australian or New Zealand site. Catalogue voltage, pump count and fan arrangement do not independently establish compliance or the required retained duty during a fault.

Continue the selection

Equipment selection enquiry

Request TC-IPS-1000 selection

Send the conditions below for a configuration-specific offer, including quantity and delivery destination.

Prepare my enquiry by email

Opens an editable email checklist; nothing is sent automatically. NDA arrangements can be agreed before confidential drawings are shared.

Include these project inputs

  • Heat duty and simultaneous inlet/outlet fluid temperatures
  • Coolant product, concentration and property source
  • External pressure-loss schedule including fouled-filter allowance
  • DN200 connection standard and installation drawing
  • Flow-control setpoint range and project electrical supply

ToneCooling Australia Pty Ltd coordinates Australian and New Zealand enquiries; manufacturing is in Huizhou, Guangdong, China. Currency, freight, delivery schedule and included inspection documents are confirmed in the quotation.

Engineering question

Can the catalogue flow and temperature rise be used as a certified thermal duty?

No. Confirm the heat balance, fluid properties, selected pump curve and accepted operating point in the project-specific offer.

By ToneCooling Engineering Team · Last updated: