Equipment selection · Australia & New Zealand

TC-DCU-2000: Integrated Dry Cooling Unit

Assess TC-DCU-2000 outdoor heat rejection for an Australian or New Zealand cooling installation. Review site air conditions, equipment access and fluid duty alongside the model PDF.

Integrated Dry Cooling Unit series reference, not an exact TC-DCU-2000 configuration
Series reference image only. Confirm the model configuration, dimensions, connections and accessories against the controlled drawing.

Selection in brief

TC-DCU-2000 is an integrated dry cooling unit with a 2000 kW catalogue capacity reference. The 13.3 m listed length and 600,000 m³/h airflow reference make outdoor layout and air recirculation important selection inputs. Confirm performance at the actual design air temperature rather than reading the operating envelope as a capacity guarantee.

Reserve the outdoor plant zone around the airflow path

The catalogue envelope is 13300 × 2280 × 2535 mm and mass is 10000 kg. Obtain the controlled drawing, support reactions, operating mass and delivery arrangement before setting foundations or planning a lift. Shipping sections, crane selection and structural adequacy cannot be established from these catalogue entries.

The liquid temperature pair is listed as 38/44.5°C, while the outdoor operating envelope extends to 45°C. These are not proof that the stated liquid temperatures and full duty are achievable at 45°C ambient. Specify the entering-air design point, recirculation allowance and whether any supplementary heat-rejection method is in scope; do not assume adiabatic assistance is included.

TC-DCU-2000 catalogue reference values

ParameterCatalogue reference
ModelTC-DCU-2000
Equipment typeIntegrated Dry Cooling Unit
Catalogue capacity2000 kW
Flow reference5000 L/min
Flow adjustment range40–100%
Head reference — confirm at required flow35 m
Power consumption reference< 115 kW
Catalogue electrical supply3-ph AC 380 V 50/60 Hz or 480 V 60 Hz
External dimensions13300 × 2280 × 2535 mm
Catalogue mass10000 kg
Pump arrangement1+1
Connection nominal size — standard to confirmDN200
Airflow reference600,000 m³/h
Liquid-side pressure-drop reference< 1.7 bar
Fan arrangementN+1
ConditionReference / action
Liquid temperature pair — direction to confirm38 °C / 44.5 °C
Outdoor operating-envelope reference−30 to 45 °C, 5–90 % RH
Thermal selectionConfirm outdoor design point, fluid and fan operation

Source: the linked ToneCooling TC-DCU-2000 model datasheet, as transcribed in the supplied catalogue material. Values are not independently verified performance or a guarantee that all fields apply at one simultaneous operating point. Confirm the document revision, fluid, temperatures, measurement boundaries, dimension orientation and mass basis in the accepted selection.

TC-DCU-2000 versus TC-DCU-1600: what to compare

Both units list a 13300 × 2280 × 2535 mm envelope. DCU-2000 lists a 38/44.5°C liquid pair; DCU-1600 lists 35/41.5°C. Their 2000 and 1600 kW references are not an equal-condition comparison. Request both selections at the same entering-air and liquid conditions.

Comparison uses the catalogue references listed on the dry cooling unit series page and its linked model datasheets. Figures are not a project performance guarantee. Confirm controlled document revisions before procurement.

Free model datasheet

TC-DCU-2000

Use this model-specific PDF for initial comparison. Request the controlled drawing and configuration-specific duty confirmation for procurement.

Download TC-DCU-2000 PDF

Free PDF · no form required. The series photograph is not a certified arrangement drawing.

Agree the supply and acceptance scope

List the equipment, connections, controls, sensors and accessories included in the offer. Assign installation, flushing, filling, electrical connection and commissioning to named project parties. Local enquiry support does not imply local stock, an included service contract or on-site installation.

Request the offered electrical schedule and applicable conformity documents for your Australian or New Zealand site. Catalogue voltage, pump count and fan arrangement do not independently establish compliance or the required retained duty during a fault.

Continue the selection

Equipment selection enquiry

Request TC-DCU-2000 selection

Send the conditions below for a configuration-specific offer, including quantity and delivery destination.

Prepare my enquiry by email

Opens an editable email checklist; nothing is sent automatically. NDA arrangements can be agreed before confidential drawings are shared.

Include these project inputs

  • Outdoor design dry-bulb temperature, altitude and recirculation allowance
  • Simultaneous heat duty, fluid temperatures and coolant mixture
  • Plan showing adjacent units, walls and intake/discharge clearance
  • Support loads, transport sections and site lifting constraints
  • Fan-out operating requirement and acoustic assessment inputs

ToneCooling Australia Pty Ltd coordinates Australian and New Zealand enquiries; manufacturing is in Huizhou, Guangdong, China. Currency, freight, delivery schedule and included inspection documents are confirmed in the quotation.

Engineering question

Does the −30 to 45°C operating envelope guarantee 2000 kW at 45°C?

No. An operating-envelope entry is not a rated capacity curve. Obtain a selection at the specified entering-air and fluid conditions, including the stated fan operating case.

By ToneCooling Engineering Team · Last updated:

Other dry coolers models

Dry coolersTC-DCU-300TC-DCU-600TC-DCU-1000TC-DCU-1600

Data centre liquid cooling

All CDUsGB300 4G+2C kitGB200 kit