Equipment selection · Australia & New Zealand

In-Row Liquid-to-Air CDUs

Compare four TC-CDU-A cabinet references for retrofit and equipment-room projects in Australia and New Zealand. Plan the room heat balance alongside the coolant circuit.

In-Row Liquid-to-Air CDUs series reference equipment
Series reference image only. It does not establish the exact model configuration, dimensions, connections or included accessories.

Selection in brief

A liquid-to-air CDU transfers coolant heat into the surrounding air stream. It can be assessed where a facility-water connection is unavailable, but the room cooling system must still remove the rejected heat. Check air intake conditions and discharge routing before selecting its liquid-side duty.

Compare models and download datasheets

Catalogue reference values

ModelCatalogue loadFlow referenceEnvelope
TC-CDU-A600C600 kW1000 L/min6000 × 1200 × 2000 mm
TC-CDU-A300C300 kW500 L/min3000 × 1200 × 2000 mm
TC-CDU-A120C120 kW200 L/min1200 × 1200 × 2000 mm
TC-CDU-A60C60 kW100 L/min600 × 1200 × 2000 mm

Source: linked ToneCooling model datasheets. Catalogue values are references, not independently verified performance or a guarantee that every listed value applies at one simultaneous duty point. Confirm fluid, temperature, external pressure, electrical configuration, dimensions and mass basis in the accepted selection.

Account for the room heat before planning a retrofit

Moving heat from a server coolant loop into room air does not remove that heat from the building. Ask the HVAC designer to assess the liquid load, unit electrical heat and other room loads at the intended operating condition. Avoid counting the same heat twice when combining server and room schedules.

Show where warm discharge travels and how it reaches the room cooling return. An obstructed intake or recirculating discharge can raise the local air temperature above the room sensor reading. Request fan, acoustic and airflow data for the selected cabinet.

Selection itemInput or referenceRequired confirmation
Air-side boundaryActual intake temperature and unobstructed airflow path.Confirm the selected thermal duty and permissible recirculation.
Room coolingAvailable sensible capacity and return-air path.Assign the HVAC assessment and residual room heat load.
Liquid loopCoolant, temperature target, flow and external pressure loss.Check duty against both air-side and liquid-side conditions.
Floor and serviceEnvelope, weight, aisle access and filter maintenance.Confirm the cabinet layout and safe maintenance sequence.

Agree the equipment and acceptance boundary

List the CDU or skid, connections, sensors, controls and accessories included in the offer. Allocate installation, water treatment, flushing, filling, electrical connection and commissioning to named project parties. Australian or New Zealand enquiry support does not imply local stock, on-site installation or an included service contract.

Request the controlled drawing, selected duty, component schedule and agreed factory test records. Confirm site electrical requirements and applicable conformity documentation for the offered configuration; a catalogue voltage or a pump arrangement is not proof of project compliance or redundancy.

Continue the selection

Equipment selection enquiry

Request In-Row Liquid-to-Air CDUs selection

Send the following conditions for a configuration-specific offer. Capacity, included equipment, documents, delivery terms and installation responsibilities must be confirmed in writing.

Prepare my enquiry by email

Opens an editable email checklist; nothing is sent automatically. Attach your drawings before sending. NDA arrangements can be agreed before you share confidential files.

Include these project inputs

  • Room intake-air range and HVAC capacity assessment
  • Liquid heat load and required supply / return temperatures
  • Coolant mixture, flow and external pressure budget
  • Airflow layout, acoustic requirement and service clearances
  • Electrical supply and room-cooling responsibility

ToneCooling Australia Pty Ltd coordinates Australian and New Zealand enquiries; manufacturing is in Huizhou, Guangdong, China. Include the destination postcode and required delivery date. Currency, freight, lead time and included inspection documents are confirmed in the quotation.

Engineering questions

Does avoiding facility-water pipework eliminate the need for room cooling?

No. The CDU rejects the liquid-loop heat to air. The room cooling arrangement must be capable of carrying that heat away.

By ToneCooling Engineering Team · Last updated:

In-row liquid-to-air models

TC-CDU-A60CTC-CDU-A120CTC-CDU-A300CTC-CDU-A600C

Other CDU series

In-rack liquid-to-liquid CDUsIn-row liquid-to-liquid CDUsIn-rack liquid-to-air CDUsDry coolersPump skidsAll CDUs