TC-CDU-A600C
TC-CDU-A600C specifications and selection
Download TC-CDU-A600C PDFFree PDF · no form required.
Compare four TC-CDU-A cabinet references for retrofit and equipment-room projects in Australia and New Zealand. Plan the room heat balance alongside the coolant circuit.

A liquid-to-air CDU transfers coolant heat into the surrounding air stream. It can be assessed where a facility-water connection is unavailable, but the room cooling system must still remove the rejected heat. Check air intake conditions and discharge routing before selecting its liquid-side duty.
TC-CDU-A600C specifications and selection
Download TC-CDU-A600C PDFFree PDF · no form required.
TC-CDU-A300C specifications and selection
Download TC-CDU-A300C PDFFree PDF · no form required.
TC-CDU-A120C specifications and selection
Download TC-CDU-A120C PDFFree PDF · no form required.
Free PDF · no form required.
| Model | Catalogue load | Flow reference | Envelope |
|---|---|---|---|
| TC-CDU-A600C | 600 kW | 1000 L/min | 6000 × 1200 × 2000 mm |
| TC-CDU-A300C | 300 kW | 500 L/min | 3000 × 1200 × 2000 mm |
| TC-CDU-A120C | 120 kW | 200 L/min | 1200 × 1200 × 2000 mm |
| TC-CDU-A60C | 60 kW | 100 L/min | 600 × 1200 × 2000 mm |
Source: linked ToneCooling model datasheets. Catalogue values are references, not independently verified performance or a guarantee that every listed value applies at one simultaneous duty point. Confirm fluid, temperature, external pressure, electrical configuration, dimensions and mass basis in the accepted selection.
Moving heat from a server coolant loop into room air does not remove that heat from the building. Ask the HVAC designer to assess the liquid load, unit electrical heat and other room loads at the intended operating condition. Avoid counting the same heat twice when combining server and room schedules.
Show where warm discharge travels and how it reaches the room cooling return. An obstructed intake or recirculating discharge can raise the local air temperature above the room sensor reading. Request fan, acoustic and airflow data for the selected cabinet.
| Selection item | Input or reference | Required confirmation |
|---|---|---|
| Air-side boundary | Actual intake temperature and unobstructed airflow path. | Confirm the selected thermal duty and permissible recirculation. |
| Room cooling | Available sensible capacity and return-air path. | Assign the HVAC assessment and residual room heat load. |
| Liquid loop | Coolant, temperature target, flow and external pressure loss. | Check duty against both air-side and liquid-side conditions. |
| Floor and service | Envelope, weight, aisle access and filter maintenance. | Confirm the cabinet layout and safe maintenance sequence. |
List the CDU or skid, connections, sensors, controls and accessories included in the offer. Allocate installation, water treatment, flushing, filling, electrical connection and commissioning to named project parties. Australian or New Zealand enquiry support does not imply local stock, on-site installation or an included service contract.
Request the controlled drawing, selected duty, component schedule and agreed factory test records. Confirm site electrical requirements and applicable conformity documentation for the offered configuration; a catalogue voltage or a pump arrangement is not proof of project compliance or redundancy.
Send the following conditions for a configuration-specific offer. Capacity, included equipment, documents, delivery terms and installation responsibilities must be confirmed in writing.
Prepare my enquiry by emailOpens an editable email checklist; nothing is sent automatically. Attach your drawings before sending. NDA arrangements can be agreed before you share confidential files.
ToneCooling Australia Pty Ltd coordinates Australian and New Zealand enquiries; manufacturing is in Huizhou, Guangdong, China. Include the destination postcode and required delivery date. Currency, freight, lead time and included inspection documents are confirmed in the quotation.
No. The CDU rejects the liquid-loop heat to air. The room cooling arrangement must be capable of carrying that heat away.